XDeersafe CS100 (Biometric) Gun Safe - Manual

cart Cart 0
Shopping Cart:

CS100 (Biometric) Gun Safe - Manual CS100 (Biometric) Gun Safe - Manual

/ Post by AntonyJansic
/ 0 comment

PRE-USE Instructions

Important Safety Instructions

  1. DO NOT use rechargeable batteries or any other type of non-alkaline battery.
  2. DO NOT mix old and new batteries. DO NOT mix alkaline and standard batteries.
  3. DO NOT lock the keys and the USB cable inside safe.
  4. Connected USB port CAN NOT charge the battery.
  5. DO NOT leave the safe in extreme weather conditions. Battery power may be affected.
  6. DO NOT store loaded firearms in this unit. Firearms are serious in nature and must be treated with respect and stored responsibly.

Unpacking Guide

Using the Backup Key to Open the safe

CS100_A_OPEN_SAFE
  1. Press the top of the key cover to reveal the key hole and insert and rotate the spare key (see Figure A).
  2. Insert the backup key and turn it, then turn the knob clockwise to open the door.

Battery Installation

  1. Press firmly on the top of the key cover, insert the spare key into the keyhole, and turn the knob clockwise to open the safe(see Figure A).
  2. Inside the safe, locate the battery compartment (see Figure B).CS100_B_BATTERY_COMPARTMENT
  3. Slide the battery cover to the right and insert 4 AA alkaline batteries (not included) into the battery compartment. Note Please note the "+" and "-" symbols (see Figure C). The "-" end of the battery is pressed against the spring in the battery compartment.CS100_C_BATTERY_DIRECTION
  4. When the battery is inserted correctly, the fuse box emits a short beeping sound.
  5. When you hear the beep, you are now ready to program the master code and fingerprint.
  • - Always use brand new AA alkaline batteries, using other batteries may render the safe inoperable.
  • - When you close the lid completely, your XDeer® safe will be locked, do not place the spare key inside the safe.

Master Code Programming

Default master code should be changed as soon as you first use it to prevent authorized persons accessing to your safe deposit box, so it should be kept confidential.

*PROGRAMMING TIPS
- The "#" key cannot be used as a code and it is the confirmation button.
- Your code can be a minimum of 3 and a maximum of 8 digits.
- Programming a new code will overwrite your previous code.

  1. Enter your master code or use backup key to open your safe, now start programming your new master code.
  2. After opening the safe, press and hold the "RESET" button for 3s (see Figure D) and then release the "RESET" button, the indicator light will blink and a beep will sound.CS100_D_RESET_BUTTON
  3. At this point, enter the new master code you want to program.
  4. After entering the new master code, press (just once) the "RESET" button, then release the "RESET" button. The light on the indicator light will blink twice and two beeps will sound. This beep will confirm that the new master control code has been programmed successfully.
  5. Now you can test your new master code (see Figure E). If you fail to program successfully, the indicator light will blink five times and five times beeps, the new master code will not work and you will only need to reprogram it from step 2.CS100_E_UNLOCK_SAFE
  6. After entering the master code and "#" key to confirm your master code, then turn the knob and the safe will be opened. When closing the safe door, please make sure to check if the safe is securely locked after turning the handle.

*Change Master Code TIP: Repeat this process to change the master code.

Programming the Biometric Scanner

Programming the Fingerprint

  1. Press and hold the "RESET" button (see Figure D) until the biometric scanner light always bright and a beep sounds.
  2. Release the "RESET" button and swipe your finger across the fingerprint scanner four times.
  3. If the indicator light blinks twice and beeps twice, the fingerprint is successfully programmed.

* Helpful Programming Tips

Deleted the Fingerprints

  1. Press and hold the "RESET" button and do not release it.
  2. There is one beep and the keypad light flashes once.
  3. No release of fingers and continue to press and hold the "RESET" button, there are two beeps and the indicator light blinks twice, then release it. (The whole process takes 5-6 seconds).
  4. All fingerprints have been deleted.
  • You must press and hold the "RESET" button from the time the backlit keypad light flashes once and beeps once to the time the backlit keypad light flashes twice and beeps twice.

Power Reminder

CS100_F_POWER_REMINDER

The indicator light on the right side of the fingerprint is the power reminder light. Press any key on the keypad to wake up the panel and check the battery level (see FIGURE F).

  • NOTE: In the process of use, if the fingerprint light is always on pink light, it indicates that the power is insufficient and the battery needs to be replaced.

*Internal LED

In order to save the loss of battery power in the safe, the internal LED will only light up when using the master code and fingerprint to unlock, and the adapter interface connected to the power supply can not make the internal LED light always on.

Sound ON/OFF

Sound ON: Hold the “1" button for 5 seconds until you hear one beep and the keypad light will flash
once together, the sound is ON.
Sound OFF: Repeat the previous step, the sound is OFF.

Backup Keys Access

Access the Safe

The keyhole is located on the top of the safe. Two backup keys are provided. In the event these are needed to open the XDeer® Safe, simply insert one of the backup keys, and turn the key to open the safe.

Using the Emergency Port

If you want to unlock your safe, but you cannot find a spare key, the safe has no battery or low battery, you can use the USB emergency interface to assist you in unlocking the safe.
The interface type belongs to Type-C (see Figure G).CS100_G_TYPE_C_PORT_POSITION
Use USB Type-C to unlock the safe with a mobile power, car power or home power, then use your fingerprint or master code, the safe can be unlocked.

  • NOTE: Cannot charge the safe using USB connection power.

Securing Your Safe

Using the Mounting Screws

  1. Fix the safe in the place which is not easy to move.
  2. Drill holes for expansion screws in the right place.
  3. Turn the expansion screws counter clockwise to separate.
  4. Use the expansion screws to secure the safe to the platform.
  5. Make sure the safe is mounted in place as required and then tighten all screws.
  • NOTE1: Use the expansion screws when there is a concrete platform surface.
  • NOTE2: Use the clamping screws when there is a wooden platform surface.

*Security Locking Mechanism

If you enter the wrong master code 5 times in a row, the keypad will be locked for 5 minutes (the indicator light and fingerprint light on the panel will flash continuously for 5 minutes ). You can stop it by using the backup key to open it and remove the battery.

PRE-USE Instructions

Important Safety Instructions

  1. DO NOT use rechargeable batteries or any other type of non-alkaline battery.
  2. DO NOT mix old and new batteries. DO NOT mix alkaline and standard batteries.
  3. DO NOT lock the keys and the USB cable inside safe.
  4. Connected USB port CAN NOT charge the battery.
  5. DO NOT leave the safe in extreme weather conditions. Battery power may be affected.
  6. DO NOT store loaded firearms in this unit. Firearms are serious in nature and must be treated with respect and stored responsibly.

Unpacking Guide

Using the Backup Key to Open the safe

CS100_A_OPEN_SAFE
  1. Press the top of the key cover to reveal the key hole and insert and rotate the spare key (see Figure A).
  2. Insert the backup key and turn it, then turn the knob clockwise to open the door.

Battery Installation

  1. Press firmly on the top of the key cover, insert the spare key into the keyhole, and turn the knob clockwise to open the safe(see Figure A).
  2. Inside the safe, locate the battery compartment (see Figure B).CS100_B_BATTERY_COMPARTMENT
  3. Slide the battery cover to the right and insert 4 AA alkaline batteries (not included) into the battery compartment. Note Please note the "+" and "-" symbols (see Figure C). The "-" end of the battery is pressed against the spring in the battery compartment.CS100_C_BATTERY_DIRECTION
  4. When the battery is inserted correctly, the fuse box emits a short beeping sound.
  5. When you hear the beep, you are now ready to program the master code and fingerprint.
  • - Always use brand new AA alkaline batteries, using other batteries may render the safe inoperable.
  • - When you close the lid completely, your XDeer® safe will be locked, do not place the spare key inside the safe.

Master Code Programming

Default master code should be changed as soon as you first use it to prevent authorized persons accessing to your safe deposit box, so it should be kept confidential.

*PROGRAMMING TIPS
- The "#" key cannot be used as a code and it is the confirmation button.
- Your code can be a minimum of 3 and a maximum of 8 digits.
- Programming a new code will overwrite your previous code.

  1. Enter your master code or use backup key to open your safe, now start programming your new master code.
  2. After opening the safe, press and hold the "RESET" button for 3s (see Figure D) and then release the "RESET" button, the indicator light will blink and a beep will sound.CS100_D_RESET_BUTTON
  3. At this point, enter the new master code you want to program.
  4. After entering the new master code, press (just once) the "RESET" button, then release the "RESET" button. The light on the indicator light will blink twice and two beeps will sound. This beep will confirm that the new master control code has been programmed successfully.
  5. Now you can test your new master code (see Figure E). If you fail to program successfully, the indicator light will blink five times and five times beeps, the new master code will not work and you will only need to reprogram it from step 2.CS100_E_UNLOCK_SAFE
  6. After entering the master code and "#" key to confirm your master code, then turn the knob and the safe will be opened. When closing the safe door, please make sure to check if the safe is securely locked after turning the handle.

*Change Master Code TIP: Repeat this process to change the master code.

Programming the Biometric Scanner

Programming the Fingerprint

  1. Press and hold the "RESET" button (see Figure D) until the biometric scanner light always bright and a beep sounds.
  2. Release the "RESET" button and swipe your finger across the fingerprint scanner four times.
  3. If the indicator light blinks twice and beeps twice, the fingerprint is successfully programmed.

* Helpful Programming Tips

Deleted the Fingerprints

  1. Press and hold the "RESET" button and do not release it.
  2. There is one beep and the keypad light flashes once.
  3. No release of fingers and continue to press and hold the "RESET" button, there are two beeps and the indicator light blinks twice, then release it. (The whole process takes 5-6 seconds).
  4. All fingerprints have been deleted.
  • You must press and hold the "RESET" button from the time the backlit keypad light flashes once and beeps once to the time the backlit keypad light flashes twice and beeps twice.

Power Reminder

CS100_F_POWER_REMINDER

The indicator light on the right side of the fingerprint is the power reminder light. Press any key on the keypad to wake up the panel and check the battery level (see FIGURE F).

  • NOTE: In the process of use, if the fingerprint light is always on pink light, it indicates that the power is insufficient and the battery needs to be replaced.

*Internal LED

In order to save the loss of battery power in the safe, the internal LED will only light up when using the master code and fingerprint to unlock, and the adapter interface connected to the power supply can not make the internal LED light always on.

Sound ON/OFF

Sound ON: Hold the “1" button for 5 seconds until you hear one beep and the keypad light will flash
once together, the sound is ON.
Sound OFF: Repeat the previous step, the sound is OFF.

Backup Keys Access

Access the Safe

The keyhole is located on the top of the safe. Two backup keys are provided. In the event these are needed to open the XDeer® Safe, simply insert one of the backup keys, and turn the key to open the safe.

Using the Emergency Port

If you want to unlock your safe, but you cannot find a spare key, the safe has no battery or low battery, you can use the USB emergency interface to assist you in unlocking the safe.
The interface type belongs to Type-C (see Figure G).CS100_G_TYPE_C_PORT_POSITION
Use USB Type-C to unlock the safe with a mobile power, car power or home power, then use your fingerprint or master code, the safe can be unlocked.

  • NOTE: Cannot charge the safe using USB connection power.

Securing Your Safe

Using the Mounting Screws

  1. Fix the safe in the place which is not easy to move.
  2. Drill holes for expansion screws in the right place.
  3. Turn the expansion screws counter clockwise to separate.
  4. Use the expansion screws to secure the safe to the platform.
  5. Make sure the safe is mounted in place as required and then tighten all screws.
  • NOTE1: Use the expansion screws when there is a concrete platform surface.
  • NOTE2: Use the clamping screws when there is a wooden platform surface.

*Security Locking Mechanism

If you enter the wrong master code 5 times in a row, the keypad will be locked for 5 minutes (the indicator light and fingerprint light on the panel will flash continuously for 5 minutes ). You can stop it by using the backup key to open it and remove the battery.